Specifications

  • Brand: Temank / listing-labelled PowMr
  • Product type: High-voltage MPPT solar charge controller
  • Battery-system voltage: 48 V DC
  • Adjustable charging current: 10–140 A
  • MPPT PV input range: 60–450 V DC
  • PV start-up voltage: 90 V DC
  • Listing-stated optimal PV operating voltage: 280 V DC
  • Maximum PV input power: 6,500 W
  • Maximum PV open-circuit voltage (Voc): 500 V DC
  • Compatible batteries: 48 V sealed, gel and flooded lead-acid; LiFePO4 and lithium-ion; user-defined charging parameters
  • Recommended PV conductor: 12 AWG (listing recommendation; verify ampacity and voltage rating for the installation)
  • Recommended battery conductor: 2 AWG (listing recommendation; verify ampacity, length and termination requirements)
  • Display: LCD with PV voltage, current, power, battery voltage, charge current, energy and fault information
  • Cooling: Dual smart fans
  • Protections: Under-voltage, over-voltage, over-charge, over-current, over-temperature and short-circuit protection
  • Operating temperature: Not published for this exact model
  • Dimensions: Not published for this exact model
  • Weight: Not published for this exact model

Product Overview

This controller is designed for 48 V battery banks and high-voltage PV strings. Its adjustable 10–140 A charge-current setting and 60–450 V MPPT window support solar arrays up to the listing-stated 6,500 W limit.

Suitable Applications

Suitable for larger off-grid 48 V battery-storage systems where the solar array, battery bank, conductors, disconnects and protective devices are professionally sized.

Compatibility and Safety Check

The PV array must operate inside the 60–450 V MPPT range and its worst-case cold-weather open-circuit voltage must remain below 500 V DC. High-voltage DC can cause fatal shock and sustained arcs. Installation should follow the supplied manual, local code and applicable high-voltage DC safety practices.