{"product_id":"120a-mppt-solar-charge-controller-12v-24v-36v-48v-60v-72v-84v-96v-battery-system-auto-solar-panel-charge-controller-regulator-lcd-display-max-input-pv-230v-for-fld-lifepo4-sld-gel-agm","title":"120A MPPT Solar Charge Controller, 12V 24V 36V 48V 60V 72V 84V 96V Battery System Auto , Solar Panel Charge Controller Regulator, LCD Display,Max Input PV 230V for FLD,LiFePO4,SLD,Gel,AGM","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\/model:\u003c\/strong\u003e EcoSolLi KY-M-YM120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e MPPT solar charge controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated charging current:\u003c\/strong\u003e 120 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery-system voltage:\u003c\/strong\u003e 12 V \/ 24 V \/ 36 V \/ 48 V \/ 60 V \/ 72 V \/ 84 V \/ 96 V DC, automatic recognition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV input operating range:\u003c\/strong\u003e Not published for this exact model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input voltage:\u003c\/strong\u003e 230 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 12 V system:\u003c\/strong\u003e 1,440 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 24 V system:\u003c\/strong\u003e 2,880 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 36 V system:\u003c\/strong\u003e 4,320 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 48 V system:\u003c\/strong\u003e 5,760 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 60 V system:\u003c\/strong\u003e 7,200 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 72 V system:\u003c\/strong\u003e 8,640 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 84 V system:\u003c\/strong\u003e 10,080 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum PV input power — 96 V system:\u003c\/strong\u003e 11,520 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPPT tracking efficiency:\u003c\/strong\u003e \u0026gt;99%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak conversion efficiency:\u003c\/strong\u003e Up to 98%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible batteries:\u003c\/strong\u003e Flooded lead-acid, sealed lead-acid, gel, AGM and LiFePO4; user-defined mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Metal housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtections:\u003c\/strong\u003e PV over-current, battery discharge, battery over-voltage, load overload, over-temperature and low-temperature charging protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e Not published for this exact model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Not published for this exact model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Not published for this exact model\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThis 120 A MPPT controller automatically recognizes battery systems from 12 V through 96 V and supports common lead-acid and LiFePO4 battery types. The maximum allowable solar wattage rises with battery-system voltage, as listed above.\u003c\/p\u003e\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\u003cp\u003eSuitable for high-current off-grid solar charging systems after confirming the exact PV operating window, conductor requirements and battery settings for the installation.\u003c\/p\u003e\u003ch2\u003eCompatibility and Safety Check\u003c\/h2\u003e\u003cp\u003eThe exact listing states a 230 V maximum PV input voltage but does not publish the controller's minimum\/start voltage or full MPPT operating range. Do not use 230 V as a target operating voltage. Obtain the supplied manual or a manufacturer rating-label confirmation before designing the PV string, and keep cold-weather array Voc below the absolute maximum.\u003c\/p\u003e\u003ch2\u003eTechnical Sources\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.amazon.ca\/dp\/B0FMDWHXSC\" target=\"_blank\" rel=\"noopener\"\u003eExact Amazon.ca listing (ASIN B0FMDWHXSC)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/manuals.plus\/asin\/B0FMDWHXSC\" target=\"_blank\" rel=\"noopener\"\u003eExact-model KY-M-YM120 manual summary\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Equipplx","offers":[{"title":"Default Title","offer_id":51321252151332,"sku":null,"price":229.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0804\/9872\/0804\/files\/51THvIXlfgL._AC_SL1500.jpg?v=1788065901","url":"https:\/\/equipplx.com\/products\/120a-mppt-solar-charge-controller-12v-24v-36v-48v-60v-72v-84v-96v-battery-system-auto-solar-panel-charge-controller-regulator-lcd-display-max-input-pv-230v-for-fld-lifepo4-sld-gel-agm","provider":"Equipplx","version":"1.0","type":"link"}